Timber Frame Installation and Clip

Technical Support

Icon Caret Product Introduction

Timber Frame Clip

All timber frame lintels must be installed with restraining clips (supplied) and should be fixed to timber frame using 3 No 3.3mm Dia x 50 long galvanized nails. The clip should overlap lintel by 12mm as indicated by a line on the clip.

Timber Frame Installation 

Lintels above 1200 long should be propped until lintel is fully loaded and brickwork has matured. Use a horizontal timber spreader to avoid distorting lintel. Use single central prop for openings up to 2100. For larger openings use multiple props (max spacing 1200).

 

 